MENSI Replacement For Carrier, Bryant and Payne Furnace Part 120V Gas Furnace Hot Surface Ignitor LH33ZS001, LH33ZS002, LH33ZS003, LH33ZS004

Free shipping on orders over $29.99

$21.99

$ 10 .99 $10.99

In Stock
  • Replacement Part For Many Carrier, Bryant, Payne, and Day & Night Furnaces
  • Replacement for Carrier Furnace Model LH33ZS001, LH33ZS001A, LH33ZS002, LH33ZS003, LH33ZS004, Ducane 20015201, Snyder General 1380672, 1380680, 1380654, Trane B138196P01, IGN26, IGN30. Robertshaw 41-409, Weil McLain 511-330-139, 511-330-193, 530-330-190.
  • Suitable for Furnace Model: 11120-100-1409, STARLITE, 1380672, SNYDER GENERAL, 1380680, 1409, 1TGF4, GRAINGER, 20015201, DUCANE HEATING CORP., 25N42, 25N4201, 271, NORTON, 41-409N, ROBERTSHAW, 511-330-139, WEIL MCLAIN, 552038, REPAIR CLINIC, 63474, UNI-LINE, 661927, BARNETT BRASS, 67920, MARS, 767A-370, WHITE-RODGERS, 90434300, RHEEM, 99911680, DS409, SURFACE IGNITOR COMPANY (SIC), DS409KX, FI-409, EATON, IG409, SUPCO, IGN00026, TRANE, IGN26, IGN-409, DIVERSITECH, L37-816, JOHNSTONE SUPPLY, LH33ZS001, CARRIER, LH33ZS001A, LH33ZS002, LH33ZS003, LH33ZS004, MB457555, SIG-409, TJIG403K, AP5324697, 2979545, ER1403, IG1403N, IG403K
  • Certified Components and Silicon Hot Rod Surface Igniter, Lift Time At Least 5000 Circles( Light and Stop work till next light asone cycle)
  • Technical Data: Rated Voltage: 120V at 50/60HZ. Cold Resistance: 5-15Ω at 77°F, Temperature At 102V at 15 Sec =>1976°F



Product Description

hot surface
120V

  • Suitable for Furnace Model: 111201001409, STARLITE, 1380672, SNYDER GENERAL, 1380680, 1409, 1TGF4, GRAINGER, 20015201, DUCANE HEATING CORP., 25N42, 25N4201, 271, NORTON, 41-409N, ROBERTSHAW, 511-330-139, WEIL MCLAIN, 552038, REPAIR CLINIC, 63474, UNI-LINE, 661927, BARNETT BRASS, 67920, MARS, 767A-370, WHITE-RODGERS, 90434300, RHEEM, 99911680, DS409, SURFACE IGNITOR COMPANY (SIC), DS409KX, FI-409, EATON, IG409, SUPCO, IGN00026, TRANE, IGN26, IGN-409, DIVERSITECH, L37-816, JOHNSTONE SUPPLY, LH33ZS001, CARRIER, LH33ZS001A, LH33ZS002, LH33ZS003, LH33ZS004, MB457555, SIG-409, TJIG403K, AP5324697, 2979545, ER1403, IG1403N, IG403K
  • Replacement for Carrier Furnace Model LH33ZS001, LH33ZS001A, LH33ZS002, LH33ZS003, LH33ZS004, Ducane 20015201, Snyder General 1380672, 1380680, 1380654, Trane B138196P01, IGN26, IGN30. Robertshaw 41-409, Weil McLain 511-330-139, 511-330-193, 530-330-190.
HOT SURFACE

Widely Used for the Furnace System

High Temperature and long life time

Nice Packing in Blister and Keep Safety of the Item.

Specifications

  • Rating Voltage: 120V/50~60HZ
  • Cold Resistance: 5-15Ω at 77F
  • Rating Current at 15 seconds: 2.1-2.9Ams at 120V±0.1
  • Temperature at 102V at 15 seconds >1976F

The 7
Reviewed in Canada on January 9, 2024
The original ignitor was silicon carbide with Carrier 8000TS furnace in year 2001.Another silicon carbide was used to replace the original one which failed in yeqr 2014.This year 2024, I bought this new type of ignitor (silicon nitride type) as a spare because the second one has been working for nearly 10 years and may fail any time.Silicon nitride type is is more robust than the silicon carbide one.
Energi
Reviewed in the United States on January 26, 2024
I got this igniter for my furnace because at a quick glance it appeared to be the same. I had to swap the connectors, but it did mount in the bracket just fine. I'm so thankful to have my furnace back up and working again. I would definitely purchase this again, but I would probably check my part numbers a bit more closely.